Supply of Single mode, 24 Core, 9-125mm OS2 UnitubeArmored OFC cable -As per specifications,Supply
Airports Authority Of India ,rhq Nr - Rangpuri
UDAIPUR, RAJASTHAN
Bid Publish Date
30-Jan-2026, 5:24 pm
Bid End Date
19-Feb-2026, 6:00 pm
EMD
₹4,35,679
Value
₹1,45,22,641
Location
Progress
Quantity
21062
Category
Supply of Hot Dip Galvanized Octagonal street light pole of 7 mtrs length
Bid Type
Two Packet Bid
Airports Authority Of India announces a tender for Supply of Hot Dip Galvanized Octagonal street light pole of 7 mtrs length, Supply of outdoor type 100W LED type flood light luminaire, Supply of outdoor type 90W LED Streetlight luminaire, Design, Fabrication, Supply, Installation, Testing and Commissioning of cubicle type, Outdoor type feeder pillar Panel, SITC of LT Feeder Pillar Panel, Supply power cable of 3. 5 X 50 sq. mm Sqmm. , Supply of XLPE insulated and PVC sheathed armoured aluminium conductor UG power cable of 4 x 16 Sqmm. , Supply of XLPE insulated and PVC sheathed armoured aluminium conductor UG power cable of 3. 5 x 300 Sqmm. , Supply of 50 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked, Supply of 63 mm OD HDPE Pipe of PE 80 PN 6, Supply of 110 mm OD HDPE Pipe of PE 80 PN 6, Supply of Underground Warning or Caution Tape size 6 x 250 mtr, Supplying and making end termination 3. 5 X 50 sq. mm, Supplying and making end termination 4 x 16 sq. mm, Supplying and making end termination 3. 5 X 300 sq. mm, Excavation for cable trenches in soft soil, Laying of Upto 63 mm dia size DWC or HDPE pipe, Laying of 110 mm dia size DWC or HDPE pipe, Laying of cable Up to 35 sq. mm in the existing RCCor HUME or DUCT or METAL or DWC or HDPE pipe as required. , Laying of cable Above 35 sq. mm and upto 95 sq. mm in the existing RCCor HUME or DUCT or METAL or DWC or HDPE pipe as required. , Laying of cable Above 185 sq. mm and upto 400 sq. mm in the existing RCCor HUME or DUCT or METAL or DWC or HDPE pipe as required. , Laying and fixing of cable Above 185 sq. mm and upto 400 sq. mm on Wall surface, Supplying and making of straight through joint with heat shrinkable kit 3. 5 X 300 sq. mm, Dismantling bituminous road by manually or mechanical, Supply and fixing of Single Arm Bracket having arm length of 1. 2 mtr, Supply and fixing of Double Arm Bracket having arm length of 1. 2 mtr, Supply of DP MCB, 6 A, C Curve, Supplying 3 Core 1. 5 Sqmm of FRLS PVC round sheathed Copper conductor Industrial cable, Erection of metallic pole upto 7 mtr length including RCC foundation, Installation, Testing, and Commissioning of 90W LED Type Street Light Fixture, Installation, Testing, and Commissioning of 100W LED Type Flood Light Fixture, Earthing with G. I. earth pipe 4. 5 meter long, 40 mm dia including accessories, Providing and fixing 6 SWG dia G. I. wire, Providing and fixing 25 mm X 5 mm G. I. strip in 40 mm dia G. I. pipe, Providing and laying in position cement concrete, Dismantling of existing street light poles up to 9 meters, Supply and erection of extra supporting MS structure with L channel, Laying of caution tape over the cable trench in COIMBATORE, TAMIL NADU. Quantity: 21062. Submission Deadline: 19-02-2026 18: 00: 00. Last date to apply is approaching fast!
Main Document
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Airports Authority Of India ,rhq Nr - Rangpuri
UDAIPUR, RAJASTHAN
Directorate General Of Lighthouses And Lightships
KOLKATA, WEST BENGAL
Directorate General Of Lighthouses And Lightships
PURI, ODISHA
Indian Army
SOLAN, HIMACHAL PRADESH
Indian Army
KOLKATA, WEST BENGAL
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Supply of Hot Dip Galvanized Octagonal street light pole of 7 mtrs length | Supply of Hot Dip Galvanized Octagonal street light pole of 7 mtrs length, 3 mm thick having minimum 130 mm bottom diameter, 70 mm top diameter with minimum 200mm x200mmx12mm size base plate and 4 nos, 16mm dia x 450 mm length J type foundation bolts/as recommended by OEM with templates and the pole should have suitable door opening at the bottom, the door opening should be reinforced, water proofed and with proper lock and Key arrangement and arrangement of in built Junction Box for terminal box with provision for connecting one number 6A DP MCB and power studs or connector to receive loop in and out loop 4 Core armoured aluminium cables of size upto 25 Sq.mm, providing M10 bolt for Earthing etc. as required. | 91 | nos | svsenthilkumar | 180 |
| 2 | Supply of outdoor type 100W LED type flood light luminaire | Supply of outdoor type 100W LED type flood light luminaire with 5700K colour temperature, Efficiency of LED Light Fitting Minimum 110lm/W, PF equal to 0.95 or more, THD should be less than 10 percent , minimum IP 65 protection with housing material made of High Pressure Die Cast Aluminium or Standard Alloy suitable for Outdoor Application with manufacturer Name/Logo embossed in the housing Body or on Aluminium Plate etc. complete as required, Surge Protection of greaterthan4KV, all prewired up to terminal block and suitable for operation on 230 V+/- 10 percent, 50Hz, single phase AC supply and as per technical specification with all its accessories, driver etc. as complete. | 30 | nos | svsenthilkumar | 180 |
| 3 | Supply of outdoor type 90W LED Streetlight luminaire | Supply of outdoor type 90W LED Streetlight luminaire having minimum output of 110 lm/watt, and designed with Powder coated Pressure Die Cast aluminium housing, frame, integral driver with Surge Protection of greaterthan4KV, Conforming to IP 65/IP66 and IK 07 protection etc. complete as required. (LED and Power Drive Should meet the AAI Specifications). | 200 | nos | svsenthilkumar | 180 |
| 4 | Design, Fabrication, Supply, Installation, Testing and Commissioning of cubicle type, Outdoor type feeder pillar Panel | Design, Fabrication, Supply, Installation, Testing and Commissioning of cubicle type, Totally enclosed, double door with sloped roof, Outdoor type (IP55 or higher), floor mounted, fully CRCA steel built feeder pillar fabricated in compartmentalized design made out of 2.0 mm thick CRCA sheet, duly powder coated in approved shade suitable for operation on 415 V, 3 phase, 4 wire, 50 Hz AC supply, TPN aluminium busbars of high conductivity, DMC or SMC busbar supports with bottom base channel with mounting legs made out of steel section of not less than 3mm thickness, entire panel shall have a common copper earth bar of size 20mm X 3 mm at the rear with 2 Nos. earth studs, solid connection from main busbar to switchgears with required size of aluminium busbar, control wiring with FRLS insulated copper conductor cables, cable alleys , cable gland plates, neoprene gaskets, terminal blocks etc to accommodate the following accessories etc. complete as required. I) Incomer MCCBs - 63 A, FP, Breaking capacity of 25kA at 415 Volts MCCB (Ics- 100 percent Icu) with Thermal magnetic release having O or L and S or C protection - 1 Set II) LED Phase Indication (R,Y,B) lamps ON and OFF indication lamps with control MCBs and 1.5 Sq.mm FRLS Copper wiring -01 Set for incomer. III) Outgoing MCCB- 63 A, FP, Breaking capacity of 25kA at 415 Volts MCCB (Ics- 100 percent Icu) with Thermal magnetic release having O or L and S or C protection - 1 Set for future provision and extension of supply IV) Outgoing MCBs - 32 A, 10 KA, 4P, C Series MCB - 5 Nos V) Common 4 Pole,100A capacity Aluminium Busbar. VI) Single dial time switch with 32A FP contactor with 2NO+2NC auxiliary contacts for the automatic switching of street light feeders -02 Set VII) Necessary Internal control wiring and earthing strip as per specifications I/C providing and fixing of suitable Rail Mounted Terminal Connectors etc. | 2 | job | svsenthilkumar | 180 |
| 5 | SITC of LT Feeder Pillar Panel | Design, engineering, fabrication, supply, transportation, installation, testing and commissioning of double door outdoor type LT Power Supply Feeder Pillar of minimum IP-54 protection, floor mounted, dust-tight and vermin-proof, cubical and compartmentalized construction, suitable for outdoor operation. The feeder pillar shall be fabricated from high-quality CRCA sheet steel of minimum 2.0 mm thickness for main enclosure and minimum 3.0 mm thickness for gland plates, stiffeners and load-bearing members. The enclosure shall be fabricated with proper bends, welded joints, gaskets, hinged doors, padlocking arrangement and provision for cable entry from bottom as per site conditions. The feeder pillar shall be suitable for operation on 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply system. The feeder pillar shall be complete with aluminium bus bars of adequate size and cross-section, having a continuous current rating of minimum 400 Amps for phase and neutral, supported on suitable non-hygroscopic, heat-resistant insulators. Separate earth bus of suitable size shall be provided throughout the panel length with two external earth terminals. The panel shall be provided with mechanical interlocking arrangement for incomers and bus coupler, three-lock two-key system for operational safety, terminal blocks for proper termination of power and control cables, danger notices, circuit identification labels, and all necessary mounting hardware. Incomer, Bus Bar and Outgoins as per SOQ mentioned in Tender Document. Refer Tender Document and Schedule of Quantities (SOQ). | 1 | job | svsenthilkumar | 180 |
| 6 | Supply power cable of 3.5 X 50 sq. mm Sqmm. | Supply of XLPE insulated and PVC sheathed armoured aluminium conductor UG power cable of 1.1 KV grade of following sizes confirming to IS 7098(Part 1 1988) with upto date amendments etc complete as required. 3.5 X 50 sq. mm Sqmm. | 370 | meter | svsenthilkumar | 180 |
| 7 | Supply of XLPE insulated and PVC sheathed armoured aluminium conductor UG power cable of 4 x 16 Sqmm. | Supply of XLPE insulated and PVC sheathed armoured aluminium conductor UG power cable of 1.1 KV grade of following sizes confirming to IS 7098(Part -1/1988) with upto date amendments etc complete as required. 4 x 16 Sqmm. | 2,000 | meter | svsenthilkumar | 180 |
| 8 | Supply of XLPE insulated and PVC sheathed armoured aluminium conductor UG power cable of 3.5 x 300 Sqmm. | Supply of XLPE insulated and PVC sheathed armoured aluminium conductor UG power cable of 1.1 KV grade of following sizes confirming to IS 7098 (Part -1/1988) with upto date amendments etc complete as required. 3.5 x 300 Sqmm. | 1,000 | meter | svsenthilkumar | 180 |
| 9 | Supply of 50 mm OD HDPE Pipe of PE 80 PN 6 ISI Marked | Supply of following OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories like HDPE socket, bend, tees, couplers etc., conforming to IS 4984 complete etc., as required. 50 mm | 1,950 | meter | svsenthilkumar | 180 |
| 10 | Supply of 63 mm OD HDPE Pipe of PE 80 PN 6 | Supply of following OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories like HDPE socket, bend, tees, couplers etc., conforming to IS 4984 complete etc., as required. 63 mm | 320 | nos | svsenthilkumar | 180 |
| 11 | Supply of 110 mm OD HDPE Pipe of PE 80 PN 6 | Supply of following OD HDPE Pipe of PE 80 PN 6 ISI Marked along with all accessories like HDPE socket, bend, tees, couplers etc., conforming to IS 4984 complete etc., as required. 110 mm | 462 | nos | svsenthilkumar | 180 |
| 12 | Supply of Underground Warning or Caution Tape size 6 x 250 mtr | Supply of Underground Warning or Caution Tape - Electric Cable Line 6, made from polyethylene tube type with printing, size 6 x 250 mtr, color Red, weight approx. 3.5 kg per roll complete as required. | 11 | nos | svsenthilkumar | 180 |
| 13 | Supplying and making end termination 3.5 X 50 sq. mm | Supplying and making end termination with double brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 X 50 sq. mm (35mm) | 4 | set | svsenthilkumar | 180 |
| 14 | Supplying and making end termination 4 x 16 sq.mm | Supplying and making end termination (w/o glands ) with aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 16 sq.mm | 214 | set | svsenthilkumar | 180 |
| 15 | Supplying and making end termination 3.5 X 300 sq. mm | Supplying and making end termination with double brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 X 300 sq. mm (70mm) | 6 | set | svsenthilkumar | 180 |
| 16 | Excavation for cable trenches in soft soil | Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc and disposal of surplus excavated soil as directed, within a lead of 50 metres. | 660 | cum | svsenthilkumar | 180 |
| 17 | Laying of Upto 63 mm dia size DWC or HDPE pipe | Laying of following size DWC/HDPE pipe along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc. Direct in ground (75 cm below ground level) in existing trench etc., complete as required. Upto 63 mm dia | 2,270 | meter | svsenthilkumar | 180 |
| 18 | Laying of 110 mm dia size DWC or HDPE pipe | Laying of following size DWC/HDPE pipe along with all accessories like socket, bend, couplers etc. complete with fitting and cutting, jointing etc. Direct in ground (75 cm below ground level) in existing trench etc., complete as required. 110 mm dia | 462 | meter | svsenthilkumar | 180 |
| 19 | Laying of cable Up to 35 sq.mm in the existing RCCor HUME or DUCT or METAL or DWC or HDPE pipe as required. | Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ DUCT/ METAL/DWC/HDPE pipe as required. Up to 35 sq.mm | 2,000 | meter | svsenthilkumar | 180 |
| 20 | Laying of cable Above 35 sq. mm and upto 95 sq. mm in the existing RCCor HUME or DUCT or METAL or DWC or HDPE pipe as required. | Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ DUCT/ METAL/DWC/HDPE pipe as required. Above 35 sq. mm and upto 95 sq. mm | 340 | meter | svsenthilkumar | 180 |
| 21 | Laying of cable Above 185 sq. mm and upto 400 sq. mm in the existing RCCor HUME or DUCT or METAL or DWC or HDPE pipe as required. | Laying of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ DUCT/ METAL/DWC/HDPE pipe as required. Above 185 sq. mm and upto 400 sq. mm | 462 | meter | svsenthilkumar | 180 |
| 22 | Laying and fixing of cable Above 185 sq. mm and upto 400 sq. mm on Wall surface | Laying and fixing of one number PVC insulated and PVC sheathed or XLPE power cable of 1.1 KV grade of following size on wall surface as required. Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) | 450 | meter | svsenthilkumar | 180 |
| 23 | Supplying and making of straight through joint with heat shrinkable kit 3.5 X 300 sq. mm | Supplying and making of straight through joint with heat shrinkable kit including ferrules and other jointing materials for the following size of PVC insulated and PVC sheathed or XLPE aluminium conductor cable of 1.1KV grade as required. 3.5 X 300 sq. mm | 1 | nos | svsenthilkumar | 180 |
| 24 | Dismantling bituminous road by manually or mechanical | Dismantling bituminous road by manually/ mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-In-Charge and Providing and laying in position cement concrete 1.2.4 (1 cement . 2 coarse sand .4 graded stone aggregate 20 mm nominal size) excluding the cost of centering and shuttering - All work up to plinth level including form work etc as required. | 5 | cum | svsenthilkumar | 180 |
| 25 | Supply and fixing of Single Arm Bracket having arm length of 1.2 mtr | Supply and fixing of the following size cross arm at top of pole, these cross arm shall be suitable for top of 7 mtr pole including 3 nos 10mm dia HDG pinch bolts, Stiffness plates etc. as required. Single Arm Bracket having arm length of 1.2 mtr | 25 | nos | svsenthilkumar | 180 |
| 26 | Supply and fixing of Double Arm Bracket having arm length of 1.2 mtr | Supply and fixing of the following size cross arm at top of pole, these cross arm shall be suitable for top of 7 mtr pole including 3 nos 10mm dia HDG pinch bolts, Stiffness plates etc. as required. Double Arm Bracket having arm length of 1.2 mtr | 66 | nos | svsenthilkumar | 180 |
| 27 | Supply of DP MCB, 6 A, C Curve | Supply of Miniature circuit breaker (MCB) having breaking capacity of 10kA suitable for operation on 230V or 415V, 50 Hz AC supply. DP MCB, 6 A, C Curve | 110 | nos | svsenthilkumar | 180 |
| 28 | Supplying 3 Core 1.5 Sqmm of FRLS PVC round sheathed Copper conductor Industrial cable | Supplying 3 Core 1.5 Sqmm of FRLS PVC round sheathed Copper conductor (Flexible) Industrial cable, 1.1 KV grade conforming to IS 694 etc as required. | 2,200 | meter | svsenthilkumar | 180 |
| 29 | Erection of metallic pole upto 7 mtr length including RCC foundation | Erection of metallic pole upto 7 mtr length including provision of RCC foundation for erection of the metallic pole (Details are mentioned in Item-4) including design of RCC foundation with resistance capacity of 296 KM/Hr Wind Speed, by providing and laying in position specified grade of reinforced cement concrete 1.3.6 (1 cement . 3 coarse sand . 6 graded stone aggregate 40 mm) and providing suitable Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in the foundation of minimum size of 450 mm(L) x 450 mm(W) x 1500 mm (H) as per OEM recommendation or Vetted Design including fixing of J bolts and providing suitable size HDPE/DWC pipe in the foundation for looping of cable, installation of suitable 4 way cable connector for connecting the loop in loop out cable inside the pole, fixing of departmentally supplied MCB, including excavation and refilling etc. complete as required. | 107 | nos | svsenthilkumar | 180 |
| 30 | Installation, Testing, and Commissioning of 90W LED Type Street Light Fixture | Installation, Testing, and Commissioning of 90W LED Type Street Light Fixture on the existing street light wall bracket with nut bolts, making inter connections from cable junction box to fitting with already supplied 3C X 1.5 Sqmm PVC insulated copper conductor cable/looping of fitting at the top of pole if required as per instructions of Engineer-In-Charge. | 200 | nos | svsenthilkumar | 180 |
| 31 | Installation, Testing, and Commissioning of 100W LED Type Flood Light Fixture | Installation, Testing, and Commissioning of 100W LED Type Flood Light Fixture on the existing street light wall bracket with nut bolts, making inter connections from cable junction box to fitting with already supplied 3C X 1.5 Sqmm PVC insulated copper conductor cable/looping of fitting at the top of pole if required as per instructions of Engineer-In-Charge. | 30 | nos | svsenthilkumar | 180 |
| 32 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with FRP cover plate of mini 2.5 ton capacity, 18x18 mini size and watering pipe etc. with charcoal/ coke and salt as required. | 11 | set | svsenthilkumar | 180 |
| 33 | Providing and fixing 6 SWG dia G.I. wire | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing including connection/ termination with GI thimble etc. as required. | 2,140 | meter | svsenthilkumar | 180 |
| 34 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode at 0.5 meter below the ground including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. | 20 | meter | svsenthilkumar | 180 |
| 35 | Providing and laying in position cement concrete | Providing and laying in position cement concrete 1.2.4 (1 cement . 2 coarse sand . 4 graded stone aggregate 20 mm nominal size) in foundation including form work etc as required. | 2 | cum | svsenthilkumar | 180 |
| 36 | Dismantling of existing street light poles up to 9 meters | Dismantling of existing street light poles up to 9 meters in height, including breaking of the concrete pedestal or by removal of nuts, washers, and other mounting accessories without causing any damage to the pole. The scope also includes dismantling of LED light fixtures, removal of cables, wires, junction boxes, and safe shifting/transportation of the dismantled poles to a designated location within a lead of 300 meters. All works shall be carried out as per site requirements and directions of the Engineer-in-Charge, including all labour, tools, equipment, and incidental charges, complete in all respects. | 60 | nos | svsenthilkumar | 180 |
| 37 | Supply and erection of extra supporting MS structure with L channel | Supply and erection of extra supporting MS structure with L channel as required for installation of flood light/street light over the pole including cutting, welding, fixing in position and applying one coat of primer, two coats of paint complete as required. | 30 | nos | svsenthilkumar | 180 |
| 38 | Laying of caution tape over the cable trench | Laying of caution tape over the cable trench at approved depth, complete as directed. | 2,750 | meter | svsenthilkumar | 180 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
National Institute Of Fashion Technology (nift) Head Office New Delhi
📍 KANGRA, HIMACHAL PRADESH
Border Security Force (bsf)
Airports Authority Of India ,rhq Nr - Rangpuri
Chandigarh International Airport Limited
📍 Mohali, PUNJAB
Bharat Sanchar Nigam Limited Portal(bsnl)
📍 NAGPUR, MAHARASHTRA
Sign up now to access all documents
Main Document
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS