Repair and Overhauling Service - diesel generators- DG Sets; REPAIR AND REWINDING OF 19 KVA GEN SET
Indian Army
BARMER, RAJASTHAN
Bid Publish Date
23-Jan-2026, 5:53 pm
Bid End Date
13-Feb-2026, 2:00 pm
EMD
₹5,00,000
Value
₹2,49,83,506
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Nhpc Limited announces a tender for Higher Rating Diesel Generating Sets (1010 kVA and above) (Q3) in CHAMBA, HIMACHAL PRADESH. Quantity: 1. Submission Deadline: 13-02-2026 14: 00: 00. Last date to apply is approaching fast!
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Army
BARMER, RAJASTHAN
Indian Army
Rangareddi, TELANGANA
Indian Air Force
BAREILLY, UTTAR PRADESH
Indian Air Force
LEH, JAMMU & KASHMIR
Indian Air Force
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| ENGINE | Type of Engine cooling | Radiator Cooled |
| ENGINE | Type of governer | Electronic, Electronic-Isochronous Or higher |
| ENGINE | Class of governer | A1, A0 Or higher |
| ENGINE | Starting System | 24 Volt Dc Electrical |
| OUTPUT CAPACITY RATING/ PHASE | Nominal Rated Capacity (kVA) | 1010 |
| ALTERNATOR | Alternator Voltage Rating | 415, 3300, 11000 |
| ALTERNATOR | Wiring System | 4 Wire, 6 Wire |
| ALTERNATOR | Voltage Regulation Grade upto 1250 kVA | NA, VG 1, VG 2, VG 3 Or higher |
| ALTERNATOR | Voltage Regulation Grade above 1250 kVA | NA, G 1, G 2, G 3 Or higher |
| CONTROL PANEL | Control Panel | AMF |
| CONTROL PANEL | Location of Control Panel | Inside the Acoustic Encolsure, Outside the Acoustic Encolsure |
| ACOUSTIC ENCLOSURE | Acoustic Enclosure inclusive in the scope of supply | With Acoustic Enclosure |
| ACOUSTIC ENCLOSURE | "Sheet Thickness of accoustic enclosure (May Specify '0' in case of without acoustic enclosure)" | 1.6 mm, 1.8 mm, 2.0 mm Or higher |
| FUEL TANK | Number of Fuel Tanks supplied with each DG Set (inclusive in the scope of supply) | 1, 2 Or higher |
| FUEL TANK | Capacity of each Fuel Tank | 990 litres Or higher |
| SCOPE OF INSTALLATION | Installation | With Installation - inclusive in the scope of supply |
| SCOPE OF INSTALLATION | Scope of installation for Diesel Generating Set(Part-1) when offered by the vendor - inclusive in the scope of supply | Scope of installation when offered by the seller (With Installation - inclusive in the scope of supply) :- a) Installation of DG Set when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation work of DG Set and its constituent parts shall be generally conforming to CPWD General specification for Electrical Works, Part - VII - latest. b) Foundation shall be constructed by the seller. Foundation shall be of PCC type with the ratio of 4:2:1. The length and breadth of the foundation shall be 300 mm more from the respective length and breadth of the DG set. The height of the foundation shall be 400 mm, i.e., 200 mm below and 200 mm above the ground level. All the materials / labour required for foundation work shall be supplied by the seller., Not Applicable as Installation not offered |
| SCOPE OF INSTALLATION | Scope of installation for Diesel Generating Set (Part 2 )when offered by the vendor - inclusive in the scope of supply | c) Supply, laying and termination of interconnecting power and control cable between Seller's supplied equipments shall be done by the seller. The interconnecting cable supplied along with each DG Set shall be of suitable current rating and shall be sufficient for a distance of 60 metres. For DG Sets having voltage rating upto 415 Volts, the cable supplied shall be ISI marked heavy duty PVC insulated, armoured cable, with PVC outer Sheath of Type ST-2 (FR Grade, Category C1), with aluminium conductor having insulation of PVC compound type -C, suitable for rated voltage upto and including 1100 volts and conforming to IS: 1554 (Part-1) latest. For DG Sets having voltage rating from 3300 Volts upto and including 33000 Volts, the cable supplied shall be ISI marked XLPE, armoured cable, with PVC outer Sheath of Type ST-2 (FR Grade, Category C1), with copper conductor having XLPE insulation, suitable for rated voltage from 3.3 kV upto and including 33 kV and conforming to IS: 7908 (Part-2) latest., Not Applicable as Installation not offered |
| SCOPE OF INSTALLATION | Scope of installation for Diesel Generating Set (Part 3 )when offered by the vendor - inclusive in the scope of supply | d) Construction of suitable earthing station and necessary connections shall be done by the seller. All the materials / labour required for construction of earthing station shall be supplied by the seller. The total number of earthing pits/stations shall be 4, i.e., 2 for neutral and 2 for body-earthing. Netutral earthing shall be done with copper Plate and Body earthing shall be done with G.I. plate / Copper. The consignee should choose installation site in such a way that the earthing stations can be made within 10 metres of the DG set. Earthing station shall be typically constructed as per prevalent standard practices and shall be generally conforming to CPWD General specification for Electrical Works, Part - VII & Part - I - latest. e) Installation of Fuel Tank(s) including foundation / stand, where applicable, shall be done by the seller., Not Applicable as Installation not offered |
| SCOPE OF INSTALLATION | Above Scope of installation for Diesel Generating Set(Part-1 + Part-2 + Part-3) when offered by the vendor has been seen, read, understood and agreed to comply | Yes, Not Applicable as Installation not offered |
| WARRANTY & SERVICING | Warranty | 24 Or higher |
| TEST REPORTS | Test report issuing authority for Engine Rating as per IS: 13018 latest / ISO 3046-latest | Engine Manufacturer |
| TEST REPORTS | Availability of Type test report for Alternator from Central government/NABL/ILAC accridited laboratory to prove conformity to the specifications | Yes |
| TEST REPORTS | If Yes, Alternator Type Test Report to be furnished to the Buyer on demand | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Indian Council Of Agricultural Research (icar)
📍 MEERUT, UTTAR PRADESH
Indian Air Force
📍 BAREILLY, UTTAR PRADESH
Indian Air Force
📍 AMBALA, HARYANA
Indian Army
📍 PUNE, MAHARASHTRA
Indian Air Force
📍 THANJAVUR, TAMIL NADU
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS