SPECTROPHOTOMETER
Kamdhenu University
📍 JAMNAGAR, GUJARAT
Progress
Quantity
1
Bid Type
Two Packet Bid
Sardarkrushinagar Dantiwada Agricultural Universit has released a public tender for SPECTROPHOTOMETER (Q2) in KACHCHH, GUJARAT. Quantity: 1. Submission Deadline: 05-08-2026 17: 00: 00. Download documents and apply online.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
SPECTROPHOTOMETER (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
36
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Pre-Bid Date
29-07-2026 15:00:00
Pre-Bid Venue
Regional Research Station, SDAU, Bhachau-kachchh-370140
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Kachchh
Delivery Pincodes
370140
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Jadeja Rajdeepsinh | 370140,REGIONAL RESEARCH STATION, SARDARKRUSHINAGAR DANTIWADA AGRICULTURAL UNIVERSITY, BHACHAU | Kachchh | Gujarat | 370140 | 1 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
| Category | Specification | Requirement |
|---|---|---|
| LIGHT SOURCE | Light Source | Halogen Lamp, Deuterium Lamp, Tungsten Halogen Lamp |
| LIGHT SOURCE | Diffraction Grating (lines/mm) | 1200 |
| LIGHT SOURCE | Switching of Light Source | Automatic |
| LIGHT SOURCE | Wavelength Setting And Scanning | Automatic |
| TYPE | Type of Spectrophotometer | UV-Visible spectrophotometer, double beam/split beam |
| TYPE | Type of Optical System | Double Beam |
| TYPE | Monochromator Type | Holographic Grating |
| TYPE | Detector Type | Photodiode |
| TYPE | Spectral Bandwidth Type | Variable Bandwidth |
| OPTICAL PERFORMANCE | Source Wavelength - Minimum | 190.0 |
| OPTICAL PERFORMANCE | Source Wavelength - Maximum | 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650 Or higher |
| OPTICAL PERFORMANCE | Resolution | 0.01 |
| OPTICAL PERFORMANCE | Wavelength Accuracy (+/-) | 0.3 |
| OPTICAL PERFORMANCE | Bandwidth (nm) | 1 |
| OPTICAL PERFORMANCE | Focal length (mm) | 100 to 149 |
| OPTICAL PERFORMANCE | Photometric measurement modes | Transmittance, Absorbance, Concentration (Wavelength, time), Reflectance |
| OPTICAL PERFORMANCE | Photometric Absorbance (Max) (Abs) (+/-) | 4 |
| OPTICAL PERFORMANCE | Photometric Absorbance Accuracy (Max) (+/-) | 0.001 - 0.001 Or lower |
| OPTICAL PERFORMANCE | Photometric Transmittance (Max) (+/-) | 100.0 |
| OPTICAL PERFORMANCE | Photometric Transmittance Accuracy (Max) (+/-) | 0.0 - 0.2 Or lower |
| OPTICAL PERFORMANCE | Photometric Reflectance (Max) (+/-) | 0.0 |
| GENERIC | Display | In-built display |
| GENERIC | Display type | LCD touchscreen |
| GENERIC | Display Size | 0 - 30 |
| GENERIC | Test result printing | Through external printer |
| GENERIC | If inbuilt printer, Type of printer | Thermal printer, Dot matrix, Laser b/w, Inkjet b/w, Color laser, Color inkjet, N/A |
| GENERIC | Connectivity | USB, WIRELESS, WIFI, Blue tooth, RS 232, N/A |
| GENERIC | Internal storage(GB) | 80.0 - 80.0 Or higher |
| GENERIC | Mximum Path Length of sample | 0 - 120 |
| GENERIC | Number of Cuvettes supplied-inclusive in the scope of supply | 10, 25, 50, 100, 200, 300, 400, 500, 2, 4, 6, 8, 0 |
| GENERIC | Spares and Consumables inclusive in the scope of supply | Yes |
| OPERATING CONDITIONS | Minimum Operating Temperature | 5.0 |
| OPERATING CONDITIONS | Maximum Operating Temperature | 40.0 |
| OPERATING CONDITIONS | Operating Humidity (RH) (%) at 40 degree C | 85.0 |
| WARRANTY | Onsite Warranty | 3.0 |
| WARRANTY | Availability of Spares (at extra cost) | 2, 3, 4, 5, 6, 7, 8, 10 |
| Certification | Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements | Yes |
| Certification | Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use | Yes |
| Certification | Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Kamdhenu University
📍 JAMNAGAR, GUJARAT
Gujarat Technological University Ahmedabad
📍 MAHESANA, GUJARAT
Sher-e-kashmir University Of Agricultural Sciences And Technology Of Jammu
📍 JAMMU, JAMMU & KASHMIR
Uranium Corporation Of India Limited
📍 EAST SINGHBHUM, JHARKHAND
Government Medical College And Hospital
📍 CHANDIGARH, CHANDIGARH
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS