Temperature Indicator for Transformers - Analog type
Uttar Pradesh Power Corporation Limited (uppcl)
BIJNOR, UTTAR PRADESH
Bid Publish Date
22-Jun-2026, 4:11 pm
Bid End Date
02-Jul-2026, 5:00 pm
Value
₹60,000
Location
Progress
Quantity
3
Bid Type
Two Packet Bid
Public procurement opportunity for Ntpc Limited Temperature Indicator for Transformers - Analog type (Q3) in VISAKHAPATNAM, ANDHRA PRADESH. Quantity: 3 issued by. Submission Deadline: 02-07-2026 17: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Temperature Indicator for Transformers - Analog type (Q3)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Uttar Pradesh Power Corporation Limited (uppcl)
BIJNOR, UTTAR PRADESH
Power Grid Corporation Of India Limited
Modern Coach Factory Raebareli
Uttar Pradesh Power Corporation Limited (uppcl)
Uranium Corporation Of India Limited
EAST SINGHBHUM, JHARKHAND
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERIC | Measuring Temperature Range | 0 deg. C to 150 deg. C |
| GENERIC | Dial Size of Temeprature Indicator (in mm) | 150, 115 |
| GENERIC | Shape of dial | Round, Segment |
| GENERIC | Degree of Ingress Protection | IP-55( as per IEC - 60529), IP-65( as per IEC - 60529) |
| CONSTRUCTION | Material of body | Aluminum die cast |
| CONSTRUCTION | Material of dial cover | Tempered glass, Polycarbonate |
| CONSTRUCTION | Max. No. of Switches (in Nos.) | 2, 4, 5 |
| CONSTRUCTION | Temerature setting by user | Yes, No |
| CONSTRUCTION | Mecury switch contact for | Alarm and Trip |
| CONSTRUCTION | Contact Rating | 5 A @ 250 Volt AC, 3 A @ 250 Volt AC, 15 A @ 250 Volt AC |
| CONSTRUCTION | Switching Range | 15% - 85% |
| CONSTRUCTION | Dial angular Sweep | 270 Deg, 60 Deg |
| CONSTRUCTION | Dial Graduation | 1 Deg C, 2 Deg C |
| CONSTRUCTION | Accuracy Class | ±1.0 % of FSD, ±1.5 % of FSD |
| CONSTRUCTION | Max Capillary tube Length | 6, 10, 18, 25 |
| CONSTRUCTION | Capillary tube material | Copper |
| CONSTRUCTION | Capillary tube protection | Stainless steel armoured and sheathed, No |
| CONSTRUCTION | Cable for Electrical Connection | 2C x 1 Sq mm. Copper Cable, 1mtr Length (as per IS:694), 2C x 2.5 Sq mm. Copper Cable, 1mtr Length (as per IS:694), 2C x 2.5 Sq mm. Copper Cable, 1mtr Length (as per IS:1554), 2C x 4 Sq mm. Copper Cable, 1mtr Length (as per IS: 1554) |
| CONSTRUCTION | High Voltage Test | "2.5 KV AC, 50Hz/60Hz for 1 min. For all Terminals to ground" |
| CONSTRUCTION | Cable Gland | Yes, No |
| Construction | Material of Body | Aluminum die cast |
| Construction | material of dial cover | Aluminum die cast |
| Construction | TTemerature setting by user | Yes, No |
| Construction | Mecury switch contact for . | Alarm and Trip |
| Construction | Contact Rating. | 5 A @ 250 Volt AC, 3 A @ 250 Volt AC, 15 A @ 250 Volt AC |
| Construction | Switching Range. | 15% - 85% |
| Construction | Dial angular Sweep. | 270 Deg, 60 Deg |
| Construction | Dial Graduation. | 1 Deg C, 2 Deg C |
| Construction | Accuracy Class. | ±1.0 % of FSD, ±1.5 % of FSD |
| Construction | Max. Capillary tube Length (in m) | 6, 10, 18, 25 |
| Construction | Capillary tube protection. | Stainless steel armoured and sheathed, No |
| Construction | Cable for Electrical Connection. | 2C x 1 Sq mm. Copper Cable, 1mtr Length (as per IS:694), 2C x 2.5 Sq mm. Copper Cable, 1mtr Length (as per IS:694), 2C x 2.5 Sq mm. Copper Cable, 1mtr Length (as per IS:1554), 2C x 4 Sq mm. Copper Cable, 1mtr Length (as per IS: 1554) |
| Construction | High Voltage Test. | "2.5 KV AC, 50Hz/60Hz for 1 min. For all Terminals to ground" |
| Construction | Cable Gland. | Yes, No |
| Transmitter and Repeater | Oil Temperature indicator supply with Transmitter (Potentio meter) with Repeater | Yes, Without transmitter and repeater |
| Transmitter and Repeater | Display | 4 digit, 5 inch, 7 segments LEDs, Without transmitter and repeater |
| Transmitter and Repeater | Auxilary supply | 90 V to 260 V AC/DC |
| Transmitter and Repeater | Resolution | 0.1 deg. C, Without transmitter and repeater |
| Transmitter and Repeater | Enclosure protection rating | IP 20 |
| Transmitter and Repeater | Operating temperature range | 0 deg. C to 60 deg. C, Without transmitter and repeater |
Discover companies most likely to bid on this tender
Indian Space Research Organization
📍 ERNAKULAM, KERALA
Nuclear Power Corporation Of India Limited
📍 SURAT, GUJARAT
Board Of Radiation And Isotope Technology
📍 THANE, MAHARASHTRA
Eastern Railway
📍 BARDHAMAN, WEST BENGAL
Hindustan Aeronautics Limited (hal)
📍 NASHIK, MAHARASHTRA
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS