Automated HPLC System for Separation of complex mixtures
Indian Council Of Agricultural Research (icar)
Bid Publish Date
10-Feb-2026, 4:46 pm
Bid End Date
24-Feb-2026, 5:00 pm
EMD
₹90,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Indian Council Of Agricultural Research (icar) invites bids for Automated HPLC System for Separation of complex mixtures (Q3) in BAREILLY, UTTAR PRADESH. Quantity: 1. Submission Deadline: 24-02-2026 17: 00: 00. Submit your proposal before the deadline.
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Council Of Agricultural Research (icar)
N/a
SOUTH DELHI, DELHI
N/a
THANJAVUR, TAMIL NADU
Central Tribal University Of Andhra Pradesh
Gujarat Technological University Ahmedabad
GANDHI NAGAR, GUJARAT
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Standard parameter | Instrument calibration standards | IEC 17025 |
| Quaternary Gradient Solvent Delivery Unit with Degassing Unit | Components of unit | Quaternary Low-Pressure Gradient pump& Parallel Double Plunger |
| Quaternary Gradient Solvent Delivery Unit with Degassing Unit | Number of solvents delivery | 4 |
| Quaternary Gradient Solvent Delivery Unit with Degassing Unit | Flow rate setting range in ml/min | 0.001 to 10 |
| Quaternary Gradient Solvent Delivery Unit with Degassing Unit | Flow rate accuracy | ± 1 % |
| UV-Vis Detector | UV-Vis Detector provided | Yes, No Or higher |
| UV-Vis Detector | Light source | NA if not provided |
| UV-Vis Detector | Spectrum Band width in nm | NA if not provided |
| UV-Vis Detector | Wavelength range in nm | NA if not provided |
| UV-Vis Detector | Sampling Rate in Hz | NA if not provided |
| UV-Vis Detector | The flow cell must be temperature Controlled | NA if not provided |
| UV-Vis Detector | Wavelength accuracy in nm | NA if not provided |
| UV-Vis Detector | Wavelength reproducibility in nm | NA if not provided |
| UV-Vis Detector | Drift in AU/Hour | NA if not provided |
| UV-Vis Detector | Noise level in AU | NA if not provided |
| UV-Vis Detector | Ability to monitor and quantitative 2 wavelengths simultaneously | NA if not provided |
| UV-Vis Detector | Linearity in AU | NA if not provided |
| UV-Vis Detector | Temperature control provided for Flow cell | NA if not provided |
| UV-Vis Detector | Temperature control range for flow cell in Degree Celsius | NA if not provided |
| UV-Vis Detector | flow cell path length in mm | NA if not provided |
| UV-Vis Detector | Flow cell volume in ?l | NA if not provided |
| Auto Sample Injector with cooler | Injection Method | Total volume sample injection |
| Auto Sample Injector with cooler | Carry over of sample | 0.005% or lower |
| Auto Sample Injector with cooler | Injection precision in RSD | less than 0.20 % RSD |
| Software | Operating Windows | Win 10 or latest |
| Photo Diode Array (PDA) Detector | Provision of Photo diode array | Yes, No Or higher |
| Photo Diode Array (PDA) Detector | PDA detector Wavelength range in nm | 190- 800 or better |
| Photo Diode Array (PDA) Detector | Number of Diodes | 1024 |
| Photo Diode Array (PDA) Detector | PDA detector light source | Deuterium lamp and Tungsten lamp |
| Photo Diode Array (PDA) Detector | PDA detector Wavelength accuracy in nm | ± 1 |
| Photo Diode Array (PDA) Detector | Data Rate in Hz | 100, <100 |
| Photo Diode Array (PDA) Detector | Noise in AU | less than ± 0.6 x 10-5 or lower |
| Photo Diode Array (PDA) Detector | PDA detector Drift in AU/Hour | less than 1 x 10-4, less than 1 x 10-3 |
| Photo Diode Array (PDA) Detector | Temperature controlled flow cell in C | 5 degree above room temp to 50 degree, NA if not provided |
| Photo Diode Array (PDA) Detector | Flow cell | Flow cell |
| Warranty & Reports | Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 2, 3, 4, 5, 1 Or higher |
| Warranty & Reports | Number of installations in Central /State/PSU Govt Hospitals | <3, >3 |
| Warranty & Reports | Availability of toll free facility for technical support maintained by OEM or authorized agencies | Yes, No Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
24-Feb-2026, 5:00 pm
Opening Date
24-Feb-2026, 5:30 pm
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS