Echo Cardiography Scanning Machine (V2)
Dr. Ram Manohar Lohia Institute Of Medical Sciences
LUCKNOW, UTTAR PRADESH
Bid Publish Date
07-Jul-2026, 6:36 pm
Bid End Date
17-Jul-2026, 7:00 pm
EMD
₹18,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
The procuring organization is Chhattisgarh Medical Services Corporation Limited under the Health And Family Welfare Department Chhattisgarh, inviting bids for an Echo Cardiography Scanning Machine (V2) in Bilaspur, Chhattisgarh (495001). The bid covers a comprehensive cardiology imaging system with wide-ranging probe configurations, including TTE, TEE (adult & pediatric), and 3D/4D capabilities, plus color Doppler, stress echo, and advanced post-processing software. An EMD of ₹18,000 is required. The system must support DICOM readiness, RIS/PACS interfacibility, and integrated reporting. The scope emphasizes high-end cardiac imaging with live 3D, tissue colorization, and extensive workflow tools. Unique features include dedicated 3D/4D volume imaging for cardiology, automated optimization, and comprehensive post-processing modules.
Echo cardiography system with full probe suite and imaging modalities
Probes: TTE, TEE (adult & pediatric), linear probes; neonatal TTE/TEE options
3D/4D volume imaging for cardiology, live 3D imaging, color Doppler with high frame rate
DICOM 3 compliant; HIS/RIS/PACS interfacability; automated CC/CM/PC reporting
Stress echo package with programmed protocols and contrast imaging support
EMD of ₹18,000 required; submission proof essential
Delivery quantity may vary up to 25% at contract and during currency
DICOM Ready system with RIS/PACS interoperability and 3D/4D capabilities
Not explicitly defined in provided data; bidders should anticipate standard government norms and seek ATC clarity
Option clause allows up to 25% quantity variation and extended delivery time; calculated extension based on (increase/original) × original delivery days, minimum 30 days
No explicit LD details in data; refer to ATC for penalty structure and performance obligations
Proven experience in supplying high-end echocardiography systems
Demonstrated capability with full probe suites including TTE/TEE and 3D/4D options
Financial strength to support procurement and warranty/AMC terms
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Echo Cardiography Scanning Machine (V2) (Q2)
Advisory Bank
HDFC Bank
ePBG Percentage
3%
ePBG Duration (Months)
42
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Pre-Bid Date
10-07-2026 12:00:00
Pre-Bid Venue
Chhattisgarh Medical Services Corporation Limited 3rd Floor, South East Corner, Vyawshayk Parisar, Sector 27, Near Mini Market, Atal Nagar, Nawa Raipur - 492015, Chhattisgarh.
Max Delivery Days
60
Delivery Locations
1
Delivery Cities
Bilaspur
Delivery Pincodes
495009
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Rakesh Nahrel | 495009,Chhattisgarh Institute of Medical Sciences (CIMS), Sardar Vallabh Bhai Patel Hospital Bilaspur (Chhattisgarh) - 495009, India | Bilaspur | Chhattisgarh | 495009 | 1 | 60 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
GEM_CATEGORY_SPECIFICATION
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Dr. Ram Manohar Lohia Institute Of Medical Sciences
LUCKNOW, UTTAR PRADESH
Eastern Railway
KOLKATA, WEST BENGAL
Tata Memorial Centre Mpmmcc And Hbch Varanasi Madh
VARANASI, UTTAR PRADESH
Hospital Medical Education
AIZAWL, MIZORAM
Directorate Of Medical Education And Training
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Types of Probes & Features | Cardiac and Vascular Probes Configuration | TTE Phased Array, TTE Matrix Array, TEE Phased Array, TEE Matrix Array, Linear Probe |
| Types of Probes & Features | TTE(Transthoracic) Probe Type | Adult, Pediatric, Neonatal |
| Types of Probes & Features | TEE Adult Probe biplane and Multiplane frequency, in MHz | 2 to 7.5 MHz (±2), Not Applicable |
| Types of Probes & Features | TEE Pediatric Probe Required | Yes, No |
| Types of Probes & Features | TEE Pediatric Probe frequency, in MHz | 3 to 8 MHz (±2), Not Applicable |
| Types of Probes & Features | Linear Probe for linear/ vascular applications required | Yes, No |
| Types of Probes & Features | Adult/Pediatric Linear probe frequency in MHz | 5 to 14 MHz (±2), 5 to 10MHz (±2), Not Applicable |
| Types of Probes & Features | No of Adult TTE Probes Required | 1, NA |
| Types of Probes & Features | No of Pediatric TTE Probes Required | 1, NA |
| Types of Probes & Features | No of Neonatal TTE Probes Required | 1, NA |
| Types of Probes & Features | No of Adult TEE Probes Required | 1, NA |
| Types of Probes & Features | No of Pediatric TEE Probes Required | 1, NA |
| Types of Probes & Features | No of Pediatric 3D/4D TEE Probes Required | 1, NA |
| Types of Probes & Features | No of Neonatal TEE Probes Required | 1, NA |
| Types of Probes & Features | No of Adult/pediatric Linear Probes supplied | 1, NA |
| Types of Probes & Features | Dedicated 3D/4D volume imaging for cardiology TTE ad TEE | Yes, No |
| Types of Probes & Features | Live 3 D imaging in color doppler system | Yes, No |
| Types of Probes & Features | Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval | Yes, No |
| Types of Probes & Features | Provision of Tissue Colorization (B-Colour) for improved contrast resolution | Yes, No |
| Types of Probes & Features | Application software | Adult, Pediatric, Neonatal, Vascular applications and Transesophagal applications |
| Types of Probes & Features | Cine Loop Features | Yes, No |
| Types of Probes & Features | Frame grabber facility for post analysis | Yes, No |
| Types of Probes & Features | Facility of Various maps for pre and post processing | Yes, No |
| Types of Probes & Features | ECG trigger facility | Yes, No |
| Types of Probes & Features | User defined Preset | Yes, No |
| Types of Probes & Features | Dedicated integrated dynamic stress echo package for flexible user defined protocols with stacked sub loops facility and contrast stress protocol usable for stress echocardiography | Yes, No |
| Types of Probes & Features | Number of transducer/probe ports | 1, 2, 3, 4 |
| Scan Modes and Performance Parameters | Cardiac 3-D freehand Option | Yes, No |
| Scan Modes and Performance Parameters | Cardiac 3D/4D automatic Option | Yes, No |
| Scan Modes and Performance Parameters | Contrast Harmonic/Agent Imaging with angio mode | Yes, No |
| Scan Modes and Performance Parameters | Color Doppler 3-D/4-D option | Yes, No |
| Scan Modes and Performance Parameters | Power Dopple 3-D/4-D option | Yes, No |
| Scan Modes and Performance Parameters | Contrast-enhanced ultrasound (CEUS) option | Yes, No |
| Scan Modes and Performance Parameters | Tissue synchronization, tissue velocity | Yes, No |
| Scan Modes and Performance Parameters | Cardiac Shear wave elastography | Yes, No |
| Scan Modes and Performance Parameters | Cardiac compression elastography | Yes, No |
| Scan Modes and Performance Parameters | Provision for higher sensitivity for low frequency doppler in all probes | Yes, No |
| Scan Modes and Performance Parameters | Latest generation Electronic Phased/sector array Colour Doppler system | Yes |
| Scan Modes and Performance Parameters | Number of Channels in color doppler system | 50000 or more (if channels are being designated as digital channels), 500000 or more (if channels are being designated as digital channels), 5000000 or more (if channels are being designated as digital channels), 128 or more (if channels are being designated as physical channels) |
| Scan Modes and Performance Parameters | System should be capable of generating real time live 3- D images | Yes, No, Yes with MV No Analysis |
| Image display and processing | DICOM 3 Compliant | Yes, No |
| Image display and processing | Automated B-mode (2-D) image | Yes, No |
| Image display and processing | Automated CDI image optimization | Yes, No |
| Image display and processing | Automated PW Doppler image optimization | Yes, No |
| Image display and processing | Touch Screen | Yes, No |
| Image display and processing | Monitor display size, cm (in) | 12 Inch(±1), 15 Inch(±1), 19 Inch(±1), 21 Inch(±1) Or higher |
| Image display and processing | Split screen | Twin View, Twin View and Live Quad Screen |
| Image display and processing | Single/dual monitors | Single, Single with optional second console, Dual (image display on touch panel) |
| Image display and processing | Speckle-tracking strain and strain rate | Yes, No |
| Image display and processing | Analysis and calculation packages | 2-D wall motion tracking, 3-D wall motion tracking, Cardiac, Mitral valve analysis, User-programmable calculations, No |
| Image display and processing | Type of printer provided with the echo cardio machine | Themal Printer, B/W Laser Printer, Color Laser Printer |
| Image display and processing | Type of processor in PC | i7 or Latest, NA |
| Image display and processing | Conectivity between Echo cardiogram and PC | Through IMS/Equivalent Software, NA |
| Image display and processing | PC with all software inclusive interfaced with echocardiograph machine | Yes, NA |
| Image display and processing | Inkjet printer provided with computer for reporting | Yes, No |
| Image display and processing | Glossy Colour Print Paper supplied | 500 sheets, 1000 sheets, Not provided |
| Image display and processing | ECG Cable | 2, NA |
| Image display and processing | Echo cardiography sytem to be DICOM Ready | Yes, No |
| Image display and processing | Dicom Interfacability to HIS | Yes, No |
| Image display and processing | Dicom Interfacability Dicom to PACS | Yes, No |
| Image display and processing | Interfacability Dicom to RIS | Yes, No |
Discover companies most likely to bid on this tender
GST registration certificate
Permanent Account Number (PAN) card
Experience certificates for prior echocardiography system supply
Financial statements (audited) for last 2-3 years
EMD submission proof (₹18,000) via DD/online
Technical bid documents showing compliance to DICOM readiness and 3D/4D capabilities
OEM authorizations for the Echo cardiography system and probes
Any BIS/IS ratings or ISO certifications (if applicable)
Key insights about CHHATTISGARH tender market
Bidders must submit GST, PAN, and EMD ₹18,000 along with technical compliance documentation showing DICOM readiness, 3D/4D capability, and RIS/PACS interoperability. OEM authorizations are required for the echo system and probes; ensure experience in high-end cardiac imaging projects and provide audited financials. Follow ATC terms for delivery and variation.
Required documents include GST certificate, PAN card, last 3 years financial statements, experience certificates of similar supply, EMD proof of ₹18,000, OEM authorization letters, and technical bid detailing DICOM readiness, probe configurations, and 3D/4D imaging features.
System must provide dedicated 3D/4D volume imaging for cardiology with live 3D, color Doppler in 3D/4D modes, harmonic imaging, and CEUS option. Includes TTE/TEE probes (adult+pediatric), linear vascular probes, ECG trigger, and post-processing tools like speckle-tracking and frame grabber.
The buyer reserves right to increase/decrease quantity up to 25% of bid quantity at contract and during currency; delivery time extends proportionally, with minimum 30 days for additional time; original delivery schedule remains reference.
System must be DICOM 3 compliant with interfacability to HIS/PACS/RIS. Requires automated B-mode, CDI, PW Doppler optimization, ECG trigger, and PC interfacing for reporting; should support inkjet printing and glossy color reports.
EMD amount is ₹18,000. Submit via demand draft or online payment as per tender ATC; ensure receipt is attached to technical bid. EMD verification is a precondition to opening financial bid and eligibility checks.
N/a
📍 SURAT, GUJARAT
All India Institute Of Medical Sciences (aiims)
📍 BHOPAL, MADHYA PRADESH
N/a
📍 CENTRAL DELHI, DELHI
Sree Chitra Tirunal Institute For Medical Sciences And Technology (sctimst)
📍 THIRUVANANTHAPURAM, KERALA
All India Institute Of Medical Sciences (aiims)
📍 NADIA, WEST BENGAL
Sign up now to access all documents
Main Document
GEM_CATEGORY_SPECIFICATION
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS