Nuclear Power Corporation of India Limited Portable Fire Extinguishers Tender Uttara Kannada Karnataka ISI 15683 2026
Nuclear Power Corporation Of India Limited
UTTARA KANNADA, KARNATAKA
Bid Publish Date
03-Jul-2026, 1:57 pm
Bid End Date
22-Jul-2026, 3:00 pm
Location
Progress
Quantity
100
Bid Type
Two Packet Bid
Public procurement opportunity for Indian Space Research Organization Portable Fire Extinguishers (V3) ISI Marked to IS 15683 (Q2) in THIRUVANANTHAPURAM, KERALA. Quantity: 100 issued by. Submission Deadline: 22-07-2026 15: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Portable Fire Extinguishers (V3) ISI Marked to IS 15683 (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
GEM_CATEGORY_SPECIFICATION
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Nuclear Power Corporation Of India Limited
UTTARA KANNADA, KARNATAKA
Indian Railway Catering And Tourism Corporation Limited
KOLKATA, WEST BENGAL
Directorate Of Animal Husbandry
AHMEDABAD, GUJARAT
Indian Space Research Organization
NELLORE, ANDHRA PRADESH
Indian Army
KAMRUP, ASSAM
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Technical Requirement | Type (Based on Extinguishing medium used) | Carbon dioxide |
| Technical Requirement | Type ( Based on Method of Discharge of extingushing medium) | Stored pressure extinguishers |
| Technical Requirement | Propellant use in Extinguishers | Carbon dioxide |
| Technical Requirement | Capacity of fire Extinguisher | 4.5 kg |
| Technical Requirement | Operating Temperature Range | + 5°C to + 60°C, 0°C to + 60°C, − 10°C to + 60°C, − 20°C to + 60°C, − 30°C to + 60°C |
| Technical Requirement | Type (Based on Service pressure of Extinguisher | Low Pressure Extinguisher (Service Pressure ≤19 bar) |
| Technical Requirement | Material of Construction | Welded low carbon steel cylinders (as per Clause 9.2.5 of IS 15683) |
| Technical Requirement | Classification of fire for which Fire Extinguisher is suitable | Class A, Class B, Class C, Class E |
| Technical Requirement | Fire Rating of different class of fires | 55B |
| Marking & Colour | Marking | As per clause 10.2 of IS 15683 |
| Marking & Colour | Colour for extinguisher Body | Red conforming to shade No. 536 or 538 of IS 5. |
| Marking & Colour | Colour coding Band | Black |
Discover companies most likely to bid on this tender
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Hindustan Petroleum Corporation Ltd
📍 VISAKHAPATNAM, ANDHRA PRADESH
Hindustan Petroleum Corporation Ltd
📍 VISAKHAPATNAM, ANDHRA PRADESH
Southern Railway
📍 ERODE, TAMIL NADU
National Rural Health Mission (nrhm) State Health Society
📍 AHMEDABAD, GUJARAT
Central Railway
📍 THANE, MAHARASHTRA
Sign up now to access all documents
Main Document
GEM_CATEGORY_SPECIFICATION
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS