Interactive Panels with CPU
Kendriya Vidyalaya Sangathan
Rangareddi, TELANGANA
Bid Publish Date
24-Jun-2026, 4:47 pm
Bid End Date
04-Jul-2026, 5:00 pm
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
The Suratgarh Super Thermal Power Station, part of Rajasthan Rajya Vidyut Utpadan Nigam Limited, invites bids for a complete Interactive Panels with CPU package. The scope spans Supply, Installation, Testing & Commissioning, plus operator training and compliance with statutory clearances if required. The project is located in Sri Ganganagar, Rajasthan. The procurement focuses on advanced display panels with CPU, touch capabilities, OPS compatibility, and on-site warranty support. A key differentiator is the integrated open pluggable specification (OPS) readiness and on-site acceptance at STPS store. The turnkey approach requires pre-dispatch and site acceptance testing aligned with buyer inspection norms.
Tender items cover Display and Touch features, CPU specs, OPS readiness, and connectivity across multiple ports. Requirements include: Display Type, Minimum Panel Size, Resolution, Nits brightness, Panel life in hours, Touch interface and points, On-site warranty (years), CPU type, cores, memory (GB), SSD capacity (GB), OPS provisioning, and optional OPS-related items (pre-install OS, memory). Ports include HDMI (input/output), USB 3.0, Audio, RJ45, USB-C; built-in speakers; Bluetooth/Wi-Fi; and accessories like extra HDMI cables. A test report from Central Govt/NABL/ILAC labs must prove conformity.
Scope of supply includes supply, installation, testing, commissioning, and operator training with any required statutory clearances. Inspections can be at seller premises (pre-dispatch) or at STPS (O&M) store for post-receipt checks. ATC has a document view; acceptance depends on pre-defined inspection outcomes. The clause emphasizes on-site acceptance, and the ATC-attached terms govern the bid process and post-delivery responsibilities.
Product/service names: Interactive display panels with CPU, OPs capable
Quantities: Not specified in BOQ (0 items listed), scope indicates single-system procurement
EMD/Estimated value: Not disclosed in data; bidders must assume standard EMD as per region
Experience requirements: Prior delivery of display panels with CPU in energy sector preferred
Quality/standards: Central Govt/NABL/ILAC lab conformity reports required
Warranty/AMC: On-site warranty support for panels and CPUs requested
Scope includes supply, installation, testing, commissioning, operator training
Inspection by nominated agency; post-receipt testing at STPS store
On-site acceptance testing and ATC-linked terms govern bid process
Payment terms to be as per ATC; details not specified in data
Delivery and installation timelines to be defined in ATC; site readiness at STPS required
LD/penalties to be specified in ATC; likely linked to delivery and performance milestones
Experience in supplying and installing interactive display panels with CPU in energy sector
Financial stability evidenced by recent financial statements
GST registration with valid compliance and ability to provide performance security
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Interactive Panels with CPU (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Kendriya Vidyalaya Sangathan
Rangareddi, TELANGANA
Kendriya Vidyalaya Sangathan
PURI, ODISHA
Directorate Of Employment & Training
Kendriya Vidyalaya Sangathan
Sivaganga, TAMIL NADU
Kendriya Vidyalaya Sangathan
RAYAGADA, ODISHA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| DISPLAY | Display Technology | In-Plane Switching (IPS) |
| DISPLAY | Display Type | Anti-Glare LCD with Direct-lit LED |
| DISPLAY | Minimum Contrast Ratio | 1200 : 1, 1300 : 1, 1400 : 1, 1500 : 1, 1600 : 1, 1700 : 1, 1800 : 1, 1900 : 1, 2000 : 1 Or higher |
| DISPLAY | Minimum Display Panel Size, Diagonal (in Inches) | 65, 75, 86, 98, 100, 105, 110 Or higher |
| DISPLAY | Minimum Display Resolution (Horizontal x Vertical) (in Pixels) | 4K UHD - 3840 x 2160 Or higher |
| DISPLAY | Display Brightness (in Nits) | 450, 500, 550, 600, 800, 1000 Or higher |
| DISPLAY | Minimum Panel Life (in Hours) | 50000 Or higher |
| TOUCH SCREEN | Touch Interface | Touch Sensitive as well as Pen Driven |
| TOUCH SCREEN | Touch Technology | Infrared (IR) |
| TOUCH SCREEN | Number of Touch Points (in Number) | 40 Or higher |
| TOUCH SCREEN | Additional Softwares | Device Management Software, NA |
| TOUCH SCREEN | On Site Warranty Support (in Years) | 3 Or higher |
| CPU | Type of CPU | Inbuilt CPU with Slot Provision for Open pluggable Specification (OPS) |
| CPU | Number of Cores | 8 Or higher |
| CPU | Memory (in GB) | 8, 16 Or higher |
| CPU | SSD Storage Capacity (in GB) | 64 Or higher |
| CPU | Provision of Slot for Open pluggable Specification (OPS) | Yes, No |
| OPTIONAL ITEM | Open pluggable Specification (OPS) included in scope of supply | Yes, No |
| OPTIONAL ITEM | Pre-Install Software (OS) for Open pluggable Specification (OPS) | Windows, Linux, NA as No OPS |
| OPTIONAL ITEM | Memory (in GB) for Open pluggable Specification (OPS) | 4, 8, 16, NA as no OPS |
| PORTS | Number of Input HDMI Ports | 2, 3, 4 Or higher |
| PORTS | Number of Output HDMI Ports | 1 Or higher |
| PORTS | Number of USB 3 Point 0 Ports | 2 |
| PORTS | Number of Audio Input Ports | 1 |
| PORTS | Number of Audio Output Ports | 1 |
| PORTS | Number of RJ 45 ports | 1, 2 Or higher |
| PORTS | USB Type C Port | 1 |
| PORTS | In-built Speakers | Yes |
| PORTS | Mounting | Wall Mount |
| CONNECTIVITY | Availability of Bluetooth Connectivity | Yes. Inbuilt, Yes. External, No Bluetooth |
| CONNECTIVITY | Bluetooth Version | 5.2, 5.3 Or higher |
| CONNECTIVITY | Availibility of Wi-Fi Connectivity | Yes. Inbuilt, No Wifi |
| CONNECTIVITY | Wi-Fi Connectivity | 802.11n (2.4 or 5 GHz) Or higher |
| ACCESSORIES | Number of Electronic Pen or Stylus Each Panel | 2 Or higher |
| ACCESSORIES | Additional HDMI Cable | 1 |
| CERTIFICATE | Availability of Test Reports from Central Govt/NABL Accredited/ILAC Accredited Lab to Prove Conformity to the Specification | Yes |
Discover companies most likely to bid on this tender
GST registration certificate
Permanent Account Number (PAN) card
Experience certificates for similar SAP/interactive display panel deployments
Financial statements or turnover proof
EMD/Security deposit as per tender norms
Technical bid documents and product compliance certificates
OEM authorisation or authorised dealer certificate
Key insights about RAJASTHAN tender market
Bidders must submit GST, PAN, experience certificates, financial statements, and EMD along with technical adherence documents. The contract requires OPS readiness, on-site warranty, and conformity reports from Central Govt/NABL/ILAC labs. Ensure installation, testing, and operator training are included as part of scope.
Required documents include GST certificate, PAN, company registration, experience certificates for similar deployments, financial statements, EMD, OEM authorisation, and technical compliance certificates proving OPS capability and display CPU integration.
Expect minimum panel size, resolution, brightness, contrast ratio, and panel life; touch interface with multiple touch points; CPU type and cores, RAM, SSD capacity, OPS slot, HDMI/USB ports, RJ45, USB-C, Bluetooth/Wi-Fi, and on-site warranty terms; conformity via NABL/ILAC labs is mandatory.
Delivery schedule is defined in ATC; installation and commissioning follow delivery. Timelines depend on site readiness at STPS store, with post-receipt inspection and acceptance testing as per buyer terms.
EMD amount and method (DD/online) are specified in tender terms; bidders should prepare the exact EMD as per ATC guidelines and ensure submission with bid documents to qualify for technical evaluation.
Bidders must provide test reports from Central Govt/NABL Accredited/ILAC Accredited labs proving conformance to the specified display and CPU standards; reports should cover display, touch, and OPS integration metrics.
On-site warranty support is expected for the display panels and CPU; terms specify duration in years and conditions for replacement or repair during the warranty period according to ATC.
Northern Railway
📍 LUCKNOW, UTTAR PRADESH
Planning And Development Department
📍 BHAGALPUR, BIHAR
Planning And Development Department
📍 BHAGALPUR, BIHAR
Planning And Development Department
📍 BHAGALPUR, BIHAR
Directorate Of Economics And Statistics
📍 SINDHUDURG, MAHARASHTRA
Sign up now to access all documents
Main Document
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS